Showing results: 166 - 180 of 340 items found.
-
Neutronics Manufacturing Co.
During installation,testing,especially if the protective gear is connected to the power line via a current transformer it is advisable to use our Primary Injection Test Set. Keeping this in mind a wide range of Primary Current Injection Test Sets are being manufactured by "NMC”.
-
SCR ELEKTRONIKS
The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!
-
Hilkar
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
WB2671A/WB2671B -
Lisun Electronics Inc.
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
Ferrites India
Rogowski Coils are mainly used to measure high current through the conductor. As opposed to conventional current transformers, Rogowski Coils are liner over wide range of current input. Rogowski Coils along with current meter are suitable for measurement of AC or DC current, up to a few thousand amperes. Ferrites India offers Flexible as well as hard Rogowski Coil which can accomodate wide conductor sizes.
-
Osborne Transformer Corp.
Osborne Potential Transformers (PT’s) are used to reduce higher system voltages to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when potential transformers are to be used for power measuring applications.
-
SEL-587 -
Schweitzer Engineering Laboratories, Inc.
The SEL-587 Current Differential/Overcurrent Relay provides protection for any two-input apparatus, such as transformers, motors, generators, and reactors. Apply it for differential and overcurrent protection and use event reports for quick post-event analysis.
-
KVZG -
KV Hipot Power Test Equipment Co.,Ltd
DC Hipot Tester is applied to measure output voltage and leakage current for zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipment.
-
CableTroll 2350 -
Nortroll
CableTroll 2350 is an indicator for detection of PtG and PtP faults on multi and single core cables. The unit uses standard type current transformers. (40:1, 60:1 or 3x500:1)
-
Shanghai Aoboor Electric Co., Ltd.
A CT lowers the current signals for measurement purposes, while a PT lowers high voltage values into lower ones. The transformers are designed to measure whether power systems are both accurate and safe.
-
Soken Electric Co. Ltd
is desirable for measuring ratio errors and phase angles of low current (voltage) transformers used in electric devices, such as watt hour meters, smart meters, digital current meters, and transducers, etc.
-
Shanghai Jiuzhi Electric Co., Ltd.
SEPS Series Energy Storage High Power Test System are self-contained test sets for high power testing without large capacity power grid support. Just typically using no more than 200kW as a charging power, the high-power test system can independently conduct the short circuit testing for power and distribution transformer, dynamical thermal stability testing for current instrument transformer and cable, short circuit current withstanding test and short circuit breaking / making capacity testing for circuit breaker and etc.
-
iDVM 333 -
Redfish Instruments, Inc.
The iDVM 333 AC Current Transducer plugs into the iDVM 510 multimeter and measures current (as AC millivolts) with no need to break the circuit. Special Introductory Price: $52.50FeaturesTransformer jaws that detect AC current flowing through a conductorSelectable sensitivity between 1mV/A and 10mV/AHand Guard to protect your hand for safetyLarge, easy-to-operate trigger opens the transformer jaws
-
HV/MV -
Ducati energia S. p. A.
Power Capacitors for medium voltage network:Ducati Energia proposal includes range of single and three-phase capacitors up to 800 kVAr with max HSV of 36kV.Upon request,we provide them with internal fuses stainless steel cases,inrush reactors,expulsion fuses as well.System is designed according to the specific application and it is composed by current transformers (CT),voltage transformers (VT) and relais.
-
NEO TELE-TRONIX PVT. LTD
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.